1. What Is Rational Robot?
Rational Robot is a complete set of components for automating the testing
of Microsoft Windows client/server and Internet applications.
The main component of Robot lets you start recording tests in as few as
two mouse clicks. After recording, Robot plays back the tests in a
fraction of the time it would take to repeat the actions manually.
2. How to create a verification point?
1. Do one of the following:
. If recording, click the Display GUI Insert Toolbar button on the GUI
Record toolbar.
. If editing, position the pointer in the script and click the Display
GUI Insert Toolbar button on the Standard toolbar.
2. Click a verification point button on the GUI Insert toolbar.
3. In the Verification Point Name dialog box, edit the name as
appropriate. The name can be a maximum of 20 characters.
4. Optionally, set the Wait state options. For information, see the next
section, Setting a Wait State for a Verification Point.
5. Optionally, set the Expected result option.
6. Click OK.
3. What is A verification point?
A verification point is a point in a script that you create to confirm
the state of an object across builds of the application-under-test.
4. How to analyz results in the log and comparators?
You use TestManager to view the logs that are created when you run
scripts and schedules.
Use the log to:
--View the results of running a script, including verification point
failures, procedural failures, aborts, and any additional playback
information. Reviewing the results in the log reveals whether each script
and verification point passed or failed.
Use the Comparators to:
--Analyze the results of verification points to determine why a script
may have failed. Robot includes four Comparators:
.Object Properties Comparator
.Text Comparator
.Grid Comparator
.Image C omparator
5. What is datapool?
A datapool is a source of variable test data that scripts can draw from
during playback.
Rational Robot Questions and Answers:
6. What is Rational Administrator?
Use the Rational Administrator to:
* create and manage projects.
* Create a project under configuration management.
* Create a project outside of configuration management.
* Connect to a project.
* See projects that are not on your machine (register a project).
* Delete a project.
* Create and manage users and groups for a Rational Test datastore.
* Create and manage projects containing Rational RequisitePro projects
and Rational Rose models.
* Manage security privileges for the entire Rational project.
* Configure a SQL Anywhere database server.
7. What is TestFactory?
Rational TestFactory is a component-based testing tool that automatically
generates TestFactory scripts according to the application’s navigational
structure. TestFactory is integrated with Robot and its components to
provide a full array of tools for team testing under Windows NT 4.0,
Windows 2000, Windows 98, and Windows 95.
With TestFactory, you can:
--Automatically create and maintain a detailed map of the application-
under-test.
--Automatically generate both scripts that provide extensive product
coverage and scripts that encounter defects, without recording.
--Track executed and unexecuted source code, and report its detailed
findings.
--Shorten the product testing cycle by minimizing the time invested in
writing navigation code.
--Play back Robot scripts in TestFactory to see extended code coverage
information and to create regression suites; play back TestFactory
scripts in Robot to debug them.
8. TestManagers wizard?
TestManager has a wizard that you can use to copy or import test scripts
and other test assets (Datapools) from one project to another.
9. How to delete a verification point and its associated files?
1. Right-click the verification point name in the Asset (left) pane and
click Delete.
2. Click the top of the script in the Script (right) pane.
3. Click Edit > Find.
4. Type the name of the deleted verification point in the Find what box.
5. Click Find Next.
6. Delete the entire line, which starts with Result=.
7. Repeat steps 5 and 6 until you have deleted all references.
10. How to rename a verification point and its associated files?
1. Right-click the verification point name in the Asset (left) pane and
click Rename.
2. Type the new name and press ENTER.
3. Click the top of the script in the Script (right) pane.
4. Click Edit > Replace.
5. Type the old name in the Find what box. Type the new name in the
Replace with box.
6. Click Replace All.
11. What is an identification method?
An identification method tells Robot how to identify the values to
compare during record and playback.
12. What is verification method?
The verification method specifies how Robot compares the baseline data
captured while recording with the data captured during playback.
13. What are two verification points for use with Web sites?
1. Use the Web Site Scan verification point to check the content of your
Web site with every revision and ensure that changes have not resulted in
defects.
2. Use the Web Site Compare verification point to capture a baseline of
your Web site and compare it to the Web site at another point in time.
14. How to add a wait state when creating a verification point?
1. Start to create the verification point.
2. In the Verification Point Name dialog box, select Apply wait state to
verification point.
3. Type values for the following options: Retry every - How often Robot
retries the verification point during playback. Robot retries until the
verification point passes or until the timeout limit is reached.
Timeout after - The maximum amount of time that Robot waits for the
verification point to pass before it times out. If the timeout limit is
reached and the verification point has not passed, Robot enters a failure
in the log. The script playback either continues or stops based on the
setting in the Error Recovery tab of the GUI Playback Options dialog box.
15. Verification point type?
Alphanumeric:
Captures and tests alphanumeric data in Windows objects that contain
text, such as edit boxes, check boxes, group boxes, labels, push buttons,
radio buttons, toolbars, and windows (captions).
2. Clipboard:
Captures and compares alphanumeric data that has been copied to the
Clipboard.
3. File Comparison:
Compares two specified files during playback.
4. File Existence:
Verifies the existence of a specified file during playback.
5. Menu:
Captures and compares the menu title, menu items, shortcut keys, and the
state of selected menus.
6. Module Existence:
Verifies whether a specified module is loaded into a specified context
(process), or is loaded anywhere in memory.
7. Object Data
Captures and compares the data inside standard Windows objects.
8. Object Properties
Captures and compares the properties of standard Windows objects.
9. Region Image
Captures a region of the screen as a bitmap.
10. Web Site Compare
Captures a baseline of a Web site and compares it to the Web site at
another point in time.
11. Web Site Scan
Checks the contents of a Web site with every revision and ensures that
changes have not resulted in defects.
12. Window Existence:
Verifies the existence and status of a specified window during playback.
13. Window Image:
Captures a window as a bitmap.
16. What is Rational SiteCheck?
Rational SiteCheck to test the structural integrity of your intranet or
World Wide Web site. SiteCheck is designed to help you view, track, and
maintain your rapidly changing site. Use SiteCheck to:
* Visualize the structure of your Web site and display the relationship
between each page and the rest of the site.
* Identify and analyze Web pages with active content, such as forms,
Java, JavaScript, ActiveX, and Visual Basic Script (VBScript).
* Filter information so that you can inspect specific file types and
defects, including broken links.
* Examine and edit the source code for any Web page, with color-coded
text.
* Update and repair files using the integrated editor, or configure your
favorite HTML editor to perform modifications to HTML files.
* Perform comprehensive testing of secure Web sites. SiteCheck provides
Secure Socket Layer (SSL) support, proxy server configuration, and
support for multiple password realms.
17. How to create a datapool?
When creating a datapool, you specify the kinds of data (called data
types) that the script will send for example, customer names, addresses,
and unique order numbers or product names. When you finish defining the
datapool, TestManager automatically generates the number of rows of data
that you specify.
18. What two kind of GUI scripts using Rational Robot?
1. functional testing
2. sessions for performance testing.
* Perform full functional testing. Record and play back scripts that
navigate through your application and test the state of objects through
verification points.
* Perform full performance testing. Use Robot and TestManager together to
record and play back sessions that help you determine whether a multi-
client system is performing within user-defined standards under varying
loads.
* Create and edit scripts using the SQABasic and VU scripting
environments. The Robot editor provides color-coded commands with keyword
Help for powerful integrated programming during script development. (VU
scripting is used with sessions in performance testing.)
* Test applications developed with IDEs such as Java, HTML, Visual Basic,
Oracle Forms, Delphi, and PowerBuilder. You can test objects even if they
are not visible in the application’s interface.
* Collect diagnostic information about an application during script
playback. Robot is integrated with Rational Purify, Rational Quantify,
and Rational PureCoverage. You can play back scripts under a diagnostic
tool and see the results in the log.
19. Which products does Rational Robot Installs with?
ClearQuest - Change-Request management tool that tracks and manages
defects and change requests through the development process.
Rational LogViewer and Comparators- are the tools you use to view logs
and test results created when you playback scripts.
Rational Robot - is the tool that you used to develop both GUI and VU
(virtual user) scripts.
SQL Anywhere - A database product to help create, maintain and run your
Rational repositories.
Rational Test Manager - is the component that you use to plan your tests,
manage your test asses, and run queries and reports.
Rational Administrator - is the component that you use to create and
manage repositories.
Rational SiteCheck - is the component that you use to test the structural
integrity of your intranet or www site.
Additional Rational Products available only with Rational Suite
TestStudio or PerformanceStudio:
Test Factory - Component based testing tool that automatically generates
TestFactory scripts according to the applications navigational structure.
Diagnostic Tools
Rational Purify - is a comprehensive C/C++ run time error checking tool.
Rational Visual Quantify - is an performance profiler that provides
performance analysis of a product, to aid in improving performance of the
code.
Rational Visual PureCoverage - is a customizable code coverage analysis
tool that provides detailed application analysis and ensure that all code
has been exercised.
Performance Studio - Tool used for automating performance tests on
client/server systems.
20. How to set the expected result when creating a verification point?
1. Start to create a verification point.
2. In the Verification Point Name dialog box, click Pass or Fail.
21. How to select the object to test?
1. Start creating the verification point.
2. In the Verification Point Name dialog box, type a name and cl ick OK
to open the Select Object dialog box.
3. Do one of the following:
. Select Automatically close dialog box after object selection to have
the Select Object dialog box close after you select the object to test.
.Clear Automatically close dialog box after object selection to have the
Select Object dialog box reappear after you select the object to test.
You will need to click OK to close the dialog box. To select a visible
object directly from the application, continue with step 4. To select an
object from a list of all objects on the desktop, skip to step 5.
4. To select a visible object directly from the application, drag the
Object Finder tool over the object and release the mouse button.
5. To select a visible or hidden object from a list of all objects on the
Windows desktop, click Browse to open the Object List dialog box. Select
the object from the list and click OK.
22. Eight verification methods?
1. Case-Sensitive - Verifies that the text captured during recording
exactly matches the captured text during playback.
2. Case-Insensitive - Verifies that the text captured during recording
matches the captured text during playback in content but not necessarily
in case.
3. Find Sub String Case-Sensitive - Verifies that the text captured
during recording exactly matches a subset of the captured text during
playback.
4. Find Sub String Case-Insensitive - Verifies that the text captured
during recording matches a subset of the captured text during playback in
content but not necessarily in case.
5. umeric Equivalence - Verifies that the values of the data captured
during recording exactly match the values captured during playback.
6. Numeric Range - Verifies that the values of the data captured during
recording fall within a specified range during playback. You specify the
From and To values for the numeric range. During playback, the
verification point verifies that the numbers are within that range.
7. User-Defined and Apply a User-Defined DLL test function - Passes text
to a function within a dynamic-link library (DLL) so that you can run
your own custom tests. You specify the path for the directory and name of
the custom DLL and the function. The verification point passes or fails
based on the result that it receives back from the DLL function.
8. Verify that selected field is blank - Verifies that the selected field
contains no text or numeric data. If the field is blank, the verification
point passes.
23. Is there four identification methods?
1. By Content - to verify that the recorded values exist during playback.
2. By Location - to verify that the recorded values exist in the same
locations during playback.
3. By Title - to verify that the recorded values remain with their titles
(names of menus or columns) during playback, even though the columns may
have changed locations.
4. By Key/Value - to verify that the recorded values in a row remain the
same during playback.
24. How to copy a verification point?
1. Right-click the verification point in the Asset (left) pane and click
Copy.
2. In the same script or in a different script (in the same project),
right-click Verification Points in the Asset pane.
3. Click Paste to paste a copy of the verification point and its
associated files into the project. If a verification point with that name
already exists, Robot appends a unique number to the name. You can also
copy and paste by dragging the verification point to Verification Points
in the Asset pane.
4. Click the top of the Script (right) pane of the original script.
5. Click Edit > Find and locate the line with the verification point name
that you just copied.
6. Select the entire line, which starts with Result=.
7. Click Edit > Copy.
8. Return to the script that you used in step 2. Click the location in
the script where you want to paste the line. Click Edit > Paste.
9. Change the name of the verification point to match the name in the
Asset pane.
25. What is TestManager?
Rational TestManager is the one place to manage all testing activities--
planning, design, implementation, execution, and analysis. TestManager
ties testing with the rest of the development effort, joining your
testing assets and tools to provide a single point from which to
understand the exact state of your project.
Test Manager supports five testing activities:
1. Plan Test.
2. Design Test.
3. Implement Test.
4. Execute Tests.
5. Evaluate Tests.
26. What is Test Requirements?
Test requirements are defined in the Requirement Hierarchy in
TestManager. The requirements hierarchy is a graphical outline of
requirements and nested child requirements.
Requirements are stored in the requisite pro database. Requisite Pro is a
tool that helps project teams control the development process by managing
and tracking the changes of requirements.
TestManager includes a baseline version of Requisite Pro. The full
version with more features and customizations is available in the
Rational Suite TestStudio.
27. How TestManager manage test logs?
When a robot scripts runs the output creates a test log. Test logs are
managed now is the TestManager application. Rational now allows you to
organize your logs into any type of format you need.
You can create a directory structures that suites your need Create build
names for each build version (or development) Create folders in which to
put the build in.
28. What is ClearQuest?
Rational ClearQuest is a change-request management tool that tracks and
manages defects and change requests throughout the development process.
With ClearQuest, you can manage every type of change activity associated
with software development, including enhancement requests, defect
reports, and documentation modifications.
With Robot and ClearQuest, you can:
-- Submit defects directly from the TestManager log or SiteCheck.
-- Modify and track defects and change requests.
-- Analyze project progress by running queries, charts, and reports.
29. How to modify or delete a custom class name?
1. Click Tools > General Options, and then click the Object Mapping tab.
2. From the Object type list, select the standard object type that is
associated with the object class name. Robot displays the class names
already available for that object type in the Object classes list.
3. From the Object classes list, select the name to modify or delete.
4. Do one of the following:
. To modify the class name, click Modify. Change the name and click OK.
. To delete the object class mapping, click Delete. Click OK at the
confirmation prompt.
5. Click OK.
30. How to create a new object order preference?
1. In an ASCII editor, create an empty text file with the extension .ord.
2. Save the file in the Dat folder of the project.
3. Click To o l s > G UI R e c o r d O p t i o n s .
4. Click the Object Recognition Order tab.
5. From the Object order preferences list, select the name of the file
you created.
6. Change the method order to customize your preferences.
31. How to change the object order preference?
1. Open the GUI Record Options dialog box.
2. Click the Object Recognition Order tab.
3. Select a preference in the Object order preference list.
4. Click OK or change other options.
32. Setting GUI Recording Options?
1. Open the GUI Record Options dialog box by doing one of the following:
--Before you start recording, click Tools > GUI Record Options.
-- Start recording by clicking the Record GUI Script button on the
toolbar.
In the Record GUI dialog box, click Options.
2. Set the options on each tab.
3. Click OK.
33. Rational diagnostic tools?
Use the Rational diagnostic tools to perform runtime error checking,
profile application performance, and analyze code coverage during
playback of a Robot script.
* Rational Purify is a comprehensive C/C++ run-time error checking tool
that automatically pinpoints run-time errors and memory leaks in all
components of an application, including third-party libraries, ensuring
that code is reliable.
* Rational Quantify is an advanced performance profiler that provides
application performance analysis, enabling developers to quickly find,
prioritize and eliminate performance bottlenecks within an application.
* Rational PureCoverage is a customizable code coverage analysis tool
that provides detailed application analysis and ensures that all code has
been exercised, preventing untested code from reaching the end-user.
34. TestManager can be used for Performance Testing?
Rational Testmanager is a sophisticated tool that can be used for
automating performance tests on client/server systems. A client/server
system includes client applications accessing a database or application
server, and browsers accessing a Web server.
Performance testing uses Rational Robot and Rational TestManager. Use
Robot to record client/server conversations and store them in scripts.
Use TestManager to schedule and play back the scripts. During playback,
TestManager can emulate hundreds, even thousands, of users placing heavy
loads and stress on your database and Web servers.
35. What is RequisitePro?
Rational RequisitePro is a requirements management tool that helps
project teams control the development process. RequisitePro organizes
your requirements by linking Microsoft Word to a requirements repository
and providing traceability and change management throughout the project
lifecycle.
36. How to set GUI recording option?
To set the GUI recording options:
1. Open the GUI Record Options dialog box by doing one of the following:
. Before you start recording, click Tools > GUI Record Options. . Start
recording by clicking the Record GUI Script button on the toolbar. In the
Record GUI dialog box, click Options.
2. Set the options on each tab.
3. Click OK.
37. How to Control Robot Responds to Unknown Objects?
1. Open the GUI Record Options dialog box.
2. In the General tab, do one of the following:
-- Select Define unknown objects as type Generic to have Robot
automatically associate unknown objects encountered while recording with
the Generic object type.
-- Clear Define unknown objects as type Generic to have Robot suspend
recording and open the Define Object dialog box if it encounters an
unknown object during recording. Use this dialog box to associate the
object with an object type.
3. Click OK or change other options.
38. How to defining an Object Class Mapping?
1. Identify the class name of the window that corresponds to the object.
You can use the Spy++ utility in Visual C++ to identify the class name.
You can also use the Robot Inspector tool by clicking Tools > Inspector.
2. In Robot, click Tools > General Options, and then click the Object
Mapping tab.
3. From the Object type list, select the standard object type to be
associated with the new object class name.
Robot displays the class names already available for that object type in
the Object classes list box.
4. Click Add.
5. Type the class name you identified in step 1 and click OK.
6. Click OK.
39. Modifying or Deleting a Custom Class Name?
1. Click Tools > General Options, and then click the Object Mapping tab.
2. From the Object type list, select the standard object type that is
associated with the object class name.
Robot displays the class names already available for that object type in
the Object classes list.
3. From the Object classes list, select the name to modify or delete.
4. Do one of the following:
- To modify the class name, click Modify. Change the name and click OK.
- To delete the object class mapping, click Delete. Click OK at the
confirmation prompt.
5. Click OK.
40. Restoring the Robot Main Window During Recording?
When Robot is minimized or is hidden behind other windows during
recording, you can bring it to the foreground in any of the following
ways:
. Click the Open Robot Window button on the GUI Record toolbar.
. Click the Robot button on the Windows taskbar.
. Use the hot key combination CTRL+SHIFT+F to display the window and
CTRL+SHIFT+H to hide the window.
41. Naming Scripts Automatically?
1. Open the GUI Record Options dialog box.
2. In the General tab, type a prefix in the Prefix box.
Clear the box if you do not want a prefix. If the box is cleared, you
will need to type a name each time you record a new script.
3. Click OK or change other options.
The next time you record a new script, the prefix and a number appear in
the Name box of the Record GUI dialog box.
In the following figure, the autonaming prefix is Test. When you record a
new script, Test7 appears in the Name box because there are six other
scripts that begin with Test.
42. How to change the order of the object recognition methods for an
object type?
1. Open the GUI Record Options dialog box.
2. Click the Object Recognition Order tab.
3. Select a preference in the Object order preference list. If you will
be testing C++ applications, change the object order preference to C++
Recognition Order.
4. From the Object type list, select the object type to modify. The fixed
set of recognition methods for the selected object type appears in the
Recognition method order list in its last saved order.
5. Select an object recognition method in the list, and then click Move
Up or Move Down. Changes made to the recognition method order take place
immediately, and cannot be undone by the Cancel button. To restore the
original default order, click Default.
6. Click OK.
Important Notes:
. Changes to the recognition method order affect scripts that are
recorded after the change. They do not affect the playback of scripts
that have already been recorded.
. Changes to the recognition method order are stored in the project. For
example, if you change the order for the CheckBox object, the new order
is stored in the project and affects all users of that project.
. Changes to the order for an object affect only the currently-selected
preference. For example, if you change the order for the CheckBox object
in the preference, the order is not changed in the C++ preference.
43. How to define an object class and map an object type to it?
1. Identify the class name of the window that corresponds to the object.
You can use the Spy++ utility in Visual C++ to identify the class name.
You can also use the Robot Inspector tool by clicking Tools > Inspector.
2. In Robot, click Tools < General Options, and then click the Object
Mapping tab.
3. From the Object type list, select the standard object type to be
associated with the new object class name. Robot displays the class names
already available for that object type in the Object classes list box.
4. Click Add.
5. Type the class name you identified in step 1 and click OK.
6. Click OK.
44. Pausing and Resuming the Recording of a Script?
To pause recording:
--Click the Pause button on the GUI Record toolbar. Robot indicates a
paused state by:
----Depressing the Pause button.
----Displaying Recording Suspended in the status bar.
----Displaying a check mark next to the Record > Pause command.
To resume recording:
-- Click Pause again.
----Always resume recording with the application-under-test in the same
state that it was in when you paused.
45. How to end the recording of a script?
Click the Stop Recording button on the GUI Record toolbar.
46. How to define script properties?
1. Do one of the following:
. If the script is open, click File > Properties.
. If the script is not open, click File > Open > Script. Select the
script and click the Properties button.
2. In the Script Properties dialog box, define the properties. For
detailed information about an item, click the question mark near the
upper-right corner of the dialog box, and then click the item.
3. Click OK.
47. How to code a script manually?
1. In Robot, click File > New > Script.
2. Type a script name (40 characters maximum) and, optionally, a
description of the script.
3. Click GUI.
4. Click OK. Robot creates an empty script with the following lines:
Sub Main
Dim Result As Integer
'Initially Recorded: 01/17/05 14:55:53
'Script Name: GUI Script
End Sub
5. Begin coding the GUI script.
48. How to add a new action to an existing script?
1. If necessary, open the script by clicking File > Open > Script.
2. If you are currently debugging, click Debug > Stop.
3. In the Script window, click where you want to insert the new actions.
Make sure that the application-under-test is in the appropriate state to
begin recording at the text cursor position.
4. Click the Insert Recording button on the Standard toolbar. The Robot
window minimizes by default, or behaves as specified in the GUI Record
Options dialog box.
5. Continue working with the application-under-test as you normally do
when recording a script.
49. How to add a feature to an existing GUI script?
1. If necessary, open the script by clicking File > Open > Script.
2. If you are currently debugging, click Debug > Stop.
3. In the Script window, click where you want to insert the feature. Make
sure that the application-under-test is in the appropriate state to
insert the feature at the text cursor position.
4. Do one of the following:
- To add the feature without going into recording mode, click the Display
GUI Insert Toolbar button on the Standard toolbar. The Robot Script
window remains open. - To start recording and add the feature, click the
Insert Recording button on the Standard toolbar. The Robot window
minimizes by default, or behaves as specified in the GUI Record Options
dialog box. Click the Display GUI Insert Toolbar button on the GUI Record
toolbar.
5. Click the appropriate button on the GUI Insert toolbar.
6. Continue adding the feature as usual.
50. How to set and clear breakpoints?
1. If necessary, open a script by clicking File > Open> Script.
2. Place the pointer on the line where you want to set a new breakpoint
or clear an existing breakpoint. You can only place a breakpoint on a
line where an SQABasic command is executed. Breakpoints on comments,
labels, and blank lines are not supported. Also, there are a very few
commands that do not support breakpoints (for example, Dim and Sub).
3. Click once to insert a blinking text cursor. (You can also highlight
the entire line or any part of the line.)
4. Click Debug > Set or Clear Breakpoint. If you set a breakpoint, Robot
inserts a solid red circle in the left margin or highlights the line. If
you clear a breakpoint, Robot removes the circle or highlighting.
5. If you set a breakpoint, click Debug > Go. Robot executes as far as
the breakpoint, and then displays a yellow arrow in the left margin of
that line or highlights the line.
51. How to insert a timer while recording or editing a script?
1. Do one of the following:
. If recording, click the Display GUI Insert Toolbar button on the GUI
Record toolbar. . If editing, position the pointer in the script and
click the Display GUI Insert Toolbar button on the Standard toolbar.
2. Click the Start Timer button on the GUI Insert toolbar.
3. Type a timer name (40 characters maximum) and click OK. If you start
more than one timer, make sure you give each timer a different name.
4. Perform the timed activity.
5. Immediately after performing the timed activity, click the Stop Timer
button on the GUI Insert toolbar.
6. Select a timer name from the list of timers you started and click OK.
52. How to insert a log message into a script during recording or
editing?
1. Do one of the following:
. If recording, click the Display GUI Insert Toolbar button on the GUI
Record toolbar.
. If editing, position the pointer in the script and click the Display
GUI Insert Toolbar button on the Standard toolbar.
2. Click the Write to Log button on the GUI Insert toolbar.
After playback, you can view logs and messages using TestManager.
53. How to Choose Network Recording?
1. Click Tools Tools Tools Tools > Session Record Options Session Record
Options Session Record Options Session Record Options.
2. Click the Method Method Method Method tab, and click Network recording
Network recording Network recording Network recording.
3. Optionally, click the Method:Network Method:Network Method:Network
Method:Network tab, and select the client/server pair that you will
record. The default is to record all of the network traffic to and from
your computer.
4. Optionally, click the Generator Filtering Generator Filtering
Generator Filtering Generator Filtering tab to specify the network
protocols to include in the script that Robot generates.
54. How to set up and use proxy recording?
# Start Robot on the proxy computer.
# In the Proxy Administration dialog box, match up the proxy computer and
port with each server to be used in the test.
# In the Method:Proxy Method:Proxy Method:Proxy Method:Proxy tab of the
Session Record Options dialog box, match up each client with the server
it will send requests to. Be sure to specify the actual server and not
the proxy computer.
# Configure each client to send requests to the proxy computer, not to
the server. For example, if the client will be sending requests to an
Oracle database, use the Oracle client configuration software to specify
the proxy computer’s address and port number, not the server’s.
# On each client computer, a tester should start the client application
and navigate to the point where recording will begin.
# On the proxy computer, enable recording (File File File File > Record
Session Record Session Record Session Record Session).
# With recording enabled, each tester at each client computer performs
the transactions to record.
# When all transactions are complete, stop recording on the proxy
computer.
55. How to create a proxy computer?
1. Click Tools Tools Tools Tools > Session Record Options Session Record
Options Session Record Options Session Record Options.
2. Click the Method Method Method Method tab and make sure that Proxy
recording Proxy recording Proxy recording Proxy recording is selected.
3. Click the Method:Proxy Method:Proxy Method:Proxy Method:Proxy tab.
4. Click Proxy Admin Proxy Admin Proxy Admin Proxy Admin.
5. In Proxy:Port Proxy:Port Proxy:Port Proxy:Port, specify the proxy
computer’s port number. Note that Robot has already detected and
specified the proxy computer’s name. You can specify any available port
number. Avoid the well-known ports (those below 1024). If you specify a
port number that is unavailable, Robot prompts you for a new port number.
6. In the Server:Port Server:Port Server:Port Server:Port list, select a
server involved in the test.
7. Click Create Proxy Create Proxy Create Proxy Create Proxy.
56. How to add a client or server computer?
If you are using network or proxy recording, and the computer that you
want to use is not listed in the Method Network and Method Proxy tabs,
you can add it to the list.
1. Click Tools > Session Record Options
2. Click the Method:Network tab or Method:Proxy tab, depending on whether
you are adding a computer for network or proxy recording.
3. Click Manage Computers.
4. Click New.
5. In the Name box of the Computers group, type a name to associate with
the network name of the computer that you are adding. You can assign any
name up to 40 characters.
6. Type the computer’s network name.
7. Optionally, click Ping to make sure that the network name you just
typed is correct. If it is correct, -Successful Ping of network name-
appears in the status bar.
8. Select Client System to list this computer as a client. Select Server
System to list this computer as a server. You can select both choices.
9. Click Add.
10. Take the following steps to use a port number with the network name.
A port number is required for servers used in proxy recording:
a. In the Ports Ports Ports Ports group, type a name to associate with
the port number that you are adding. You can assign any name up to 40
characters.
b. Type the port number to use with the computer’s network name.
c. Click Apply, then OK .
11. Click Close Close Close Close.
57. How to Recording a Single Script in a Session?
1. In Robot, click the Record Session button. Alternatively, click File >
Record Session, or press CTRL+SHIFT+R.
2. Ty p e t h e session name (40 characters maximum), or accept the
default name. You will specify the script name when you finish recording
the script. If you have not yet set your session recording options, do so
now by clicking Options.
3. Click OK in the Record Session - Enter Session Name dialog box. The
following events occur:
. Robot is minimized (default behavior).
. The Session Record floating toolbar appears (default behavior). You can
use this toolbar to stop recording, redisplay Robot, split a script, and
insert features into a script.
. The Session Recorder icon appears on the taskbar. The icon blinks as
Robot captures requests and responses.
4. If the Start Application dialog box is displayed, provide the
following information, and click OK:
. The path of the executable file for the browser or database
application.
. Optionally, the working directory for any components (such as DLLs)
that the client application needs at runtime.
. Optionally, any arguments that you want to pass to the client
application. The Start Application dialog box appears only if you are
performing API recording, or if you are performing network or proxy
recording and selected Prompt for application name on start recording in
the General tab of the Session Record Options dialog box.
5. Perform the transactions that you want to record. As the application
sends requests to the server, notice the activity in the Session Recorder
window. Progress bars and request statistics appear in the top of the
window.
If there is no activity in the Session Recorder window (or if the Session
Recorder icon never blinks), there is a problem with the recording. Stop
recording and try to find the cause of the problem.
6. Optionally, insert features such as blocks and timers through the
Session Insert floating toolbar or through the Robot Insert menu.
7. Optionally, when you finish recording transactions, close the client
application. With API recording, when you close the client, Robot asks
whether you want to stop recording. If so, click Yes, and either name the
session or click to ignore the recorded information in the Generating
Scripts dialog box.
8. Click the Stop Recording button on the Session Record floating
toolbar.
58. How to stop recording and generate scripts in a Session?
1. Click the Stop Recording button on the Session Record floating
toolbar.
2. In the Name of the just-recorded script box, type or select a name for
the script that you just finished recording, or accept the default name.
3. Click OK.
59. How to see error message If problems occur during script generation?
the error message appears in the status bar of the Generating Scripts
dialog box like this: "Completed with warnings and/or errors"
To see the list of errors, click Details. If the text of an error is
truncated, you can either:
. Double-click the text to see the entire message.
. Press CTRL+C to copy the text to the Clipboard.
60. How to cancelling a Script in a Single-Script Session?
1. During recording, click the Stop button on the Session Record floating
toolbar.
2. In the Stop Recording dialog box, click Ignore just-recorded
information.
3. Click OK in the Stop Recording dialog box.
4. Click OK to acknowledge that the session is being deleted.
61. When would you want to split a session?
If quick script development time is a priority - perhaps because testable
builds are developed daily, or because web content is updated daily.
62. How to split a session into multiple scripts?
1. During recording, at the point where you want to end one script and
begin a new one, click the Split Script button on the Session Record
floating toolbar.
2. Enter a name for the script that you are ending, or accept the default
name.
3. Click OK.
4. Repeat the previous steps as many times as needed to end one script
and begin another. 5. After you click the Stop Recording button to end
the recording session, type or select a name for the last script you
recorded, or accept the default name.
63. How to regenerate Scripts from a Session?
1. In Robot, click Tools > Regenerate Test Scripts from Session.
2. Click the name of the session to use.
3. Click OK to acknowledge that the regeneration operation is complete.
64. How Timers Work?
1. Start the timer (click Insert--Start Timer) just before you click the
button to send the query. This action inserts the VU emulation command
start_time into the script.
2. Stop the timer (click Insert --Stop Timer) as soon as the results
appear. This action inserts the VU emulation command stop_time into the
script.
65. What is a block?
A block is a set of contiguous lines of code that you want to make
distinct from the rest of the script.
66. What is a blocks characteristics?
# A block begins with the comment. In the VU language, a block begins
like this:
/* Start_Block "BlockName" */
# Robot automatically starts a timer at the start of the block. In the VU
language, the timer looks like this:
start_time ["BlockName"] _fs_ts;
Typically, the start_time emulation command is inserted after the first
action, but with an argument to use a read-only variable that refers to
the start of the first action.
# The ID of every emulation command in a block is constructed the same
way that is, by the block name followed by a unique, three-digit
autonumber. For example, in the VU language:
http_header_recv ["BlockName002"] 200;
When you end a block, command IDs are constructed as they were before you
started the block. For example, if the last command ID before the block
was Script025, the next command ID after the block will be Script026.
# A block ends with a stop_time command plus a comment. For example, in
the VU language:
stop_time ["BlockName"]; /* Stop_Block */
67. Why Use Blocks?
. To associate the block and timer names with the emulation command that
performs the transaction.
. To include the block name in TestManager reports, thus enabling you to
filter the reports with the block name.
.To make the script easier to read, and to provide an immediate context
for a line within the block through command IDs.
68. How to insert a block into a script?
1. If the Session Insert floating toolbar is not already displayed, click
the Insert button on the Session Record floating toolbar.
2. Click the Start Block button at that point in the script where you
want the block to begin for example, just before you start to record a
transaction.
3. Type the block name. Robot uses this name as the prefix for all
command IDs in the block. The maximum number of characters for a command
ID prefix is seven.
4. Click OK.
5. Record all of the client requests in the block.
6. Click the Stop Block button to end the current block, and click OK.
7. Continue recording the other sections of the script. When you start
and stop a block during recording, the commands are reported as
annotations in the Annotations window.
69. What is A synchronization point?
A synchronization point lets you coordinate the activities of a number of
virtual testers by pausing the execution of each tester at a particular
point
70. Why Use Synchronization Points?
By synchronizing virtual testers to perform the same activity at the same
time, you can make that activity occur at some particular point of
interest in your test. Typically, synchronization points that you insert
into scripts are used in conjunction with timers to determine the effect
of varying workload on the timed activity.
Rational Robot Multiple Choice Questions and Answers PDF Experienced Freshers
1. What Is Rational Robot?
Rational Robot is a complete set of components for automating the testing
of Microsoft Windows client/server and Internet applications.
The main component of Robot lets you start recording tests in as few as
two mouse clicks. After recording, Robot plays back the tests in a
fraction of the time it would take to repeat the actions manually.
2. How to create a verification point?
1. Do one of the following:
. If recording, click the Display GUI Insert Toolbar button on the GUI
Record toolbar.
. If editing, position the pointer in the script and click the Display
GUI Insert Toolbar button on the Standard toolbar.
2. Click a verification point button on the GUI Insert toolbar.
3. In the Verification Point Name dialog box, edit the name as
appropriate. The name can be a maximum of 20 characters.
4. Optionally, set the Wait state options. For information, see the next
section, Setting a Wait State for a Verification Point.
5. Optionally, set the Expected result option.
6. Click OK.
3. What is A verification point?
A verification point is a point in a script that you create to confirm
the state of an object across builds of the application-under-test.
4. How to analyz results in the log and comparators?
You use TestManager to view the logs that are created when you run
scripts and schedules.
Use the log to:
--View the results of running a script, including verification point
failures, procedural failures, aborts, and any additional playback
information. Reviewing the results in the log reveals whether each script
and verification point passed or failed.
Use the Comparators to:
--Analyze the results of verification points to determine why a script
may have failed. Robot includes four Comparators:
.Object Properties Comparator
.Text Comparator
.Grid Comparator
.Image C omparator
5. What is datapool?
A datapool is a source of variable test data that scripts can draw from
during playback.
Rational Robot Questions and Answers:
6. What is Rational Administrator?
Use the Rational Administrator to:
* create and manage projects.
* Create a project under configuration management.
* Create a project outside of configuration management.
* Connect to a project.
* See projects that are not on your machine (register a project).
* Delete a project.
* Create and manage users and groups for a Rational Test datastore.
* Create and manage projects containing Rational RequisitePro projects
and Rational Rose models.
* Manage security privileges for the entire Rational project.
* Configure a SQL Anywhere database server.
7. What is TestFactory?
Rational TestFactory is a component-based testing tool that automatically
generates TestFactory scripts according to the application’s navigational
structure. TestFactory is integrated with Robot and its components to
provide a full array of tools for team testing under Windows NT 4.0,
Windows 2000, Windows 98, and Windows 95.
With TestFactory, you can:
--Automatically create and maintain a detailed map of the application-
under-test.
--Automatically generate both scripts that provide extensive product
coverage and scripts that encounter defects, without recording.
--Track executed and unexecuted source code, and report its detailed
findings.
--Shorten the product testing cycle by minimizing the time invested in
writing navigation code.
--Play back Robot scripts in TestFactory to see extended code coverage
information and to create regression suites; play back TestFactory
scripts in Robot to debug them.
8. TestManagers wizard?
TestManager has a wizard that you can use to copy or import test scripts
and other test assets (Datapools) from one project to another.
9. How to delete a verification point and its associated files?
1. Right-click the verification point name in the Asset (left) pane and
click Delete.
2. Click the top of the script in the Script (right) pane.
3. Click Edit > Find.
4. Type the name of the deleted verification point in the Find what box.
5. Click Find Next.
6. Delete the entire line, which starts with Result=.
7. Repeat steps 5 and 6 until you have deleted all references.
10. How to rename a verification point and its associated files?
1. Right-click the verification point name in the Asset (left) pane and
click Rename.
2. Type the new name and press ENTER.
3. Click the top of the script in the Script (right) pane.
4. Click Edit > Replace.
5. Type the old name in the Find what box. Type the new name in the
Replace with box.
6. Click Replace All.
11. What is an identification method?
An identification method tells Robot how to identify the values to
compare during record and playback.
12. What is verification method?
The verification method specifies how Robot compares the baseline data
captured while recording with the data captured during playback.
13. What are two verification points for use with Web sites?
1. Use the Web Site Scan verification point to check the content of your
Web site with every revision and ensure that changes have not resulted in
defects.
2. Use the Web Site Compare verification point to capture a baseline of
your Web site and compare it to the Web site at another point in time.
14. How to add a wait state when creating a verification point?
1. Start to create the verification point.
2. In the Verification Point Name dialog box, select Apply wait state to
verification point.
3. Type values for the following options: Retry every - How often Robot
retries the verification point during playback. Robot retries until the
verification point passes or until the timeout limit is reached.
Timeout after - The maximum amount of time that Robot waits for the
verification point to pass before it times out. If the timeout limit is
reached and the verification point has not passed, Robot enters a failure
in the log. The script playback either continues or stops based on the
setting in the Error Recovery tab of the GUI Playback Options dialog box.
15. Verification point type?
Alphanumeric:
Captures and tests alphanumeric data in Windows objects that contain
text, such as edit boxes, check boxes, group boxes, labels, push buttons,
radio buttons, toolbars, and windows (captions).
2. Clipboard:
Captures and compares alphanumeric data that has been copied to the
Clipboard.
3. File Comparison:
Compares two specified files during playback.
4. File Existence:
Verifies the existence of a specified file during playback.
5. Menu:
Captures and compares the menu title, menu items, shortcut keys, and the
state of selected menus.
6. Module Existence:
Verifies whether a specified module is loaded into a specified context
(process), or is loaded anywhere in memory.
7. Object Data
Captures and compares the data inside standard Windows objects.
8. Object Properties
Captures and compares the properties of standard Windows objects.
9. Region Image
Captures a region of the screen as a bitmap.
10. Web Site Compare
Captures a baseline of a Web site and compares it to the Web site at
another point in time.
11. Web Site Scan
Checks the contents of a Web site with every revision and ensures that
changes have not resulted in defects.
12. Window Existence:
Verifies the existence and status of a specified window during playback.
13. Window Image:
Captures a window as a bitmap.
16. What is Rational SiteCheck?
Rational SiteCheck to test the structural integrity of your intranet or
World Wide Web site. SiteCheck is designed to help you view, track, and
maintain your rapidly changing site. Use SiteCheck to:
* Visualize the structure of your Web site and display the relationship
between each page and the rest of the site.
* Identify and analyze Web pages with active content, such as forms,
Java, JavaScript, ActiveX, and Visual Basic Script (VBScript).
* Filter information so that you can inspect specific file types and
defects, including broken links.
* Examine and edit the source code for any Web page, with color-coded
text.
* Update and repair files using the integrated editor, or configure your
favorite HTML editor to perform modifications to HTML files.
* Perform comprehensive testing of secure Web sites. SiteCheck provides
Secure Socket Layer (SSL) support, proxy server configuration, and
support for multiple password realms.
17. How to create a datapool?
When creating a datapool, you specify the kinds of data (called data
types) that the script will send for example, customer names, addresses,
and unique order numbers or product names. When you finish defining the
datapool, TestManager automatically generates the number of rows of data
that you specify.
18. What two kind of GUI scripts using Rational Robot?
1. functional testing
2. sessions for performance testing.
* Perform full functional testing. Record and play back scripts that
navigate through your application and test the state of objects through
verification points.
* Perform full performance testing. Use Robot and TestManager together to
record and play back sessions that help you determine whether a multi-
client system is performing within user-defined standards under varying
loads.
* Create and edit scripts using the SQABasic and VU scripting
environments. The Robot editor provides color-coded commands with keyword
Help for powerful integrated programming during script development. (VU
scripting is used with sessions in performance testing.)
* Test applications developed with IDEs such as Java, HTML, Visual Basic,
Oracle Forms, Delphi, and PowerBuilder. You can test objects even if they
are not visible in the application’s interface.
* Collect diagnostic information about an application during script
playback. Robot is integrated with Rational Purify, Rational Quantify,
and Rational PureCoverage. You can play back scripts under a diagnostic
tool and see the results in the log.
19. Which products does Rational Robot Installs with?
ClearQuest - Change-Request management tool that tracks and manages
defects and change requests through the development process.
Rational LogViewer and Comparators- are the tools you use to view logs
and test results created when you playback scripts.
Rational Robot - is the tool that you used to develop both GUI and VU
(virtual user) scripts.
SQL Anywhere - A database product to help create, maintain and run your
Rational repositories.
Rational Test Manager - is the component that you use to plan your tests,
manage your test asses, and run queries and reports.
Rational Administrator - is the component that you use to create and
manage repositories.
Rational SiteCheck - is the component that you use to test the structural
integrity of your intranet or www site.
Additional Rational Products available only with Rational Suite
TestStudio or PerformanceStudio:
Test Factory - Component based testing tool that automatically generates
TestFactory scripts according to the applications navigational structure.
Diagnostic Tools
Rational Purify - is a comprehensive C/C++ run time error checking tool.
Rational Visual Quantify - is an performance profiler that provides
performance analysis of a product, to aid in improving performance of the
code.
Rational Visual PureCoverage - is a customizable code coverage analysis
tool that provides detailed application analysis and ensure that all code
has been exercised.
Performance Studio - Tool used for automating performance tests on
client/server systems.
20. How to set the expected result when creating a verification point?
1. Start to create a verification point.
2. In the Verification Point Name dialog box, click Pass or Fail.
21. How to select the object to test?
1. Start creating the verification point.
2. In the Verification Point Name dialog box, type a name and cl ick OK
to open the Select Object dialog box.
3. Do one of the following:
. Select Automatically close dialog box after object selection to have
the Select Object dialog box close after you select the object to test.
.Clear Automatically close dialog box after object selection to have the
Select Object dialog box reappear after you select the object to test.
You will need to click OK to close the dialog box. To select a visible
object directly from the application, continue with step 4. To select an
object from a list of all objects on the desktop, skip to step 5.
4. To select a visible object directly from the application, drag the
Object Finder tool over the object and release the mouse button.
5. To select a visible or hidden object from a list of all objects on the
Windows desktop, click Browse to open the Object List dialog box. Select
the object from the list and click OK.
22. Eight verification methods?
1. Case-Sensitive - Verifies that the text captured during recording
exactly matches the captured text during playback.
2. Case-Insensitive - Verifies that the text captured during recording
matches the captured text during playback in content but not necessarily
in case.
3. Find Sub String Case-Sensitive - Verifies that the text captured
during recording exactly matches a subset of the captured text during
playback.
4. Find Sub String Case-Insensitive - Verifies that the text captured
during recording matches a subset of the captured text during playback in
content but not necessarily in case.
5. umeric Equivalence - Verifies that the values of the data captured
during recording exactly match the values captured during playback.
6. Numeric Range - Verifies that the values of the data captured during
recording fall within a specified range during playback. You specify the
From and To values for the numeric range. During playback, the
verification point verifies that the numbers are within that range.
7. User-Defined and Apply a User-Defined DLL test function - Passes text
to a function within a dynamic-link library (DLL) so that you can run
your own custom tests. You specify the path for the directory and name of
the custom DLL and the function. The verification point passes or fails
based on the result that it receives back from the DLL function.
8. Verify that selected field is blank - Verifies that the selected field
contains no text or numeric data. If the field is blank, the verification
point passes.
23. Is there four identification methods?
1. By Content - to verify that the recorded values exist during playback.
2. By Location - to verify that the recorded values exist in the same
locations during playback.
3. By Title - to verify that the recorded values remain with their titles
(names of menus or columns) during playback, even though the columns may
have changed locations.
4. By Key/Value - to verify that the recorded values in a row remain the
same during playback.
24. How to copy a verification point?
1. Right-click the verification point in the Asset (left) pane and click
Copy.
2. In the same script or in a different script (in the same project),
right-click Verification Points in the Asset pane.
3. Click Paste to paste a copy of the verification point and its
associated files into the project. If a verification point with that name
already exists, Robot appends a unique number to the name. You can also
copy and paste by dragging the verification point to Verification Points
in the Asset pane.
4. Click the top of the Script (right) pane of the original script.
5. Click Edit > Find and locate the line with the verification point name
that you just copied.
6. Select the entire line, which starts with Result=.
7. Click Edit > Copy.
8. Return to the script that you used in step 2. Click the location in
the script where you want to paste the line. Click Edit > Paste.
9. Change the name of the verification point to match the name in the
Asset pane.
25. What is TestManager?
Rational TestManager is the one place to manage all testing activities--
planning, design, implementation, execution, and analysis. TestManager
ties testing with the rest of the development effort, joining your
testing assets and tools to provide a single point from which to
understand the exact state of your project.
Test Manager supports five testing activities:
1. Plan Test.
2. Design Test.
3. Implement Test.
4. Execute Tests.
5. Evaluate Tests.
26. What is Test Requirements?
Test requirements are defined in the Requirement Hierarchy in
TestManager. The requirements hierarchy is a graphical outline of
requirements and nested child requirements.
Requirements are stored in the requisite pro database. Requisite Pro is a
tool that helps project teams control the development process by managing
and tracking the changes of requirements.
TestManager includes a baseline version of Requisite Pro. The full
version with more features and customizations is available in the
Rational Suite TestStudio.
27. How TestManager manage test logs?
When a robot scripts runs the output creates a test log. Test logs are
managed now is the TestManager application. Rational now allows you to
organize your logs into any type of format you need.
You can create a directory structures that suites your need Create build
names for each build version (or development) Create folders in which to
put the build in.
28. What is ClearQuest?
Rational ClearQuest is a change-request management tool that tracks and
manages defects and change requests throughout the development process.
With ClearQuest, you can manage every type of change activity associated
with software development, including enhancement requests, defect
reports, and documentation modifications.
With Robot and ClearQuest, you can:
-- Submit defects directly from the TestManager log or SiteCheck.
-- Modify and track defects and change requests.
-- Analyze project progress by running queries, charts, and reports.
29. How to modify or delete a custom class name?
1. Click Tools > General Options, and then click the Object Mapping tab.
2. From the Object type list, select the standard object type that is
associated with the object class name. Robot displays the class names
already available for that object type in the Object classes list.
3. From the Object classes list, select the name to modify or delete.
4. Do one of the following:
. To modify the class name, click Modify. Change the name and click OK.
. To delete the object class mapping, click Delete. Click OK at the
confirmation prompt.
5. Click OK.
30. How to create a new object order preference?
1. In an ASCII editor, create an empty text file with the extension .ord.
2. Save the file in the Dat folder of the project.
3. Click To o l s > G UI R e c o r d O p t i o n s .
4. Click the Object Recognition Order tab.
5. From the Object order preferences list, select the name of the file
you created.
6. Change the method order to customize your preferences.
31. How to change the object order preference?
1. Open the GUI Record Options dialog box.
2. Click the Object Recognition Order tab.
3. Select a preference in the Object order preference list.
4. Click OK or change other options.
32. Setting GUI Recording Options?
1. Open the GUI Record Options dialog box by doing one of the following:
--Before you start recording, click Tools > GUI Record Options.
-- Start recording by clicking the Record GUI Script button on the
toolbar.
In the Record GUI dialog box, click Options.
2. Set the options on each tab.
3. Click OK.
33. Rational diagnostic tools?
Use the Rational diagnostic tools to perform runtime error checking,
profile application performance, and analyze code coverage during
playback of a Robot script.
* Rational Purify is a comprehensive C/C++ run-time error checking tool
that automatically pinpoints run-time errors and memory leaks in all
components of an application, including third-party libraries, ensuring
that code is reliable.
* Rational Quantify is an advanced performance profiler that provides
application performance analysis, enabling developers to quickly find,
prioritize and eliminate performance bottlenecks within an application.
* Rational PureCoverage is a customizable code coverage analysis tool
that provides detailed application analysis and ensures that all code has
been exercised, preventing untested code from reaching the end-user.
34. TestManager can be used for Performance Testing?
Rational Testmanager is a sophisticated tool that can be used for
automating performance tests on client/server systems. A client/server
system includes client applications accessing a database or application
server, and browsers accessing a Web server.
Performance testing uses Rational Robot and Rational TestManager. Use
Robot to record client/server conversations and store them in scripts.
Use TestManager to schedule and play back the scripts. During playback,
TestManager can emulate hundreds, even thousands, of users placing heavy
loads and stress on your database and Web servers.
35. What is RequisitePro?
Rational RequisitePro is a requirements management tool that helps
project teams control the development process. RequisitePro organizes
your requirements by linking Microsoft Word to a requirements repository
and providing traceability and change management throughout the project
lifecycle.
36. How to set GUI recording option?
To set the GUI recording options:
1. Open the GUI Record Options dialog box by doing one of the following:
. Before you start recording, click Tools > GUI Record Options. . Start
recording by clicking the Record GUI Script button on the toolbar. In the
Record GUI dialog box, click Options.
2. Set the options on each tab.
3. Click OK.
37. How to Control Robot Responds to Unknown Objects?
1. Open the GUI Record Options dialog box.
2. In the General tab, do one of the following:
-- Select Define unknown objects as type Generic to have Robot
automatically associate unknown objects encountered while recording with
the Generic object type.
-- Clear Define unknown objects as type Generic to have Robot suspend
recording and open the Define Object dialog box if it encounters an
unknown object during recording. Use this dialog box to associate the
object with an object type.
3. Click OK or change other options.
38. How to defining an Object Class Mapping?
1. Identify the class name of the window that corresponds to the object.
You can use the Spy++ utility in Visual C++ to identify the class name.
You can also use the Robot Inspector tool by clicking Tools > Inspector.
2. In Robot, click Tools > General Options, and then click the Object
Mapping tab.
3. From the Object type list, select the standard object type to be
associated with the new object class name.
Robot displays the class names already available for that object type in
the Object classes list box.
4. Click Add.
5. Type the class name you identified in step 1 and click OK.
6. Click OK.
39. Modifying or Deleting a Custom Class Name?
1. Click Tools > General Options, and then click the Object Mapping tab.
2. From the Object type list, select the standard object type that is
associated with the object class name.
Robot displays the class names already available for that object type in
the Object classes list.
3. From the Object classes list, select the name to modify or delete.
4. Do one of the following:
- To modify the class name, click Modify. Change the name and click OK.
- To delete the object class mapping, click Delete. Click OK at the
confirmation prompt.
5. Click OK.
40. Restoring the Robot Main Window During Recording?
When Robot is minimized or is hidden behind other windows during
recording, you can bring it to the foreground in any of the following
ways:
. Click the Open Robot Window button on the GUI Record toolbar.
. Click the Robot button on the Windows taskbar.
. Use the hot key combination CTRL+SHIFT+F to display the window and
CTRL+SHIFT+H to hide the window.
41. Naming Scripts Automatically?
1. Open the GUI Record Options dialog box.
2. In the General tab, type a prefix in the Prefix box.
Clear the box if you do not want a prefix. If the box is cleared, you
will need to type a name each time you record a new script.
3. Click OK or change other options.
The next time you record a new script, the prefix and a number appear in
the Name box of the Record GUI dialog box.
In the following figure, the autonaming prefix is Test. When you record a
new script, Test7 appears in the Name box because there are six other
scripts that begin with Test.
42. How to change the order of the object recognition methods for an
object type?
1. Open the GUI Record Options dialog box.
2. Click the Object Recognition Order tab.
3. Select a preference in the Object order preference list. If you will
be testing C++ applications, change the object order preference to C++
Recognition Order.
4. From the Object type list, select the object type to modify. The fixed
set of recognition methods for the selected object type appears in the
Recognition method order list in its last saved order.
5. Select an object recognition method in the list, and then click Move
Up or Move Down. Changes made to the recognition method order take place
immediately, and cannot be undone by the Cancel button. To restore the
original default order, click Default.
6. Click OK.
Important Notes:
. Changes to the recognition method order affect scripts that are
recorded after the change. They do not affect the playback of scripts
that have already been recorded.
. Changes to the recognition method order are stored in the project. For
example, if you change the order for the CheckBox object, the new order
is stored in the project and affects all users of that project.
. Changes to the order for an object affect only the currently-selected
preference. For example, if you change the order for the CheckBox object
in the preference, the order is not changed in the C++ preference.
43. How to define an object class and map an object type to it?
1. Identify the class name of the window that corresponds to the object.
You can use the Spy++ utility in Visual C++ to identify the class name.
You can also use the Robot Inspector tool by clicking Tools > Inspector.
2. In Robot, click Tools < General Options, and then click the Object
Mapping tab.
3. From the Object type list, select the standard object type to be
associated with the new object class name. Robot displays the class names
already available for that object type in the Object classes list box.
4. Click Add.
5. Type the class name you identified in step 1 and click OK.
6. Click OK.
44. Pausing and Resuming the Recording of a Script?
To pause recording:
--Click the Pause button on the GUI Record toolbar. Robot indicates a
paused state by:
----Depressing the Pause button.
----Displaying Recording Suspended in the status bar.
----Displaying a check mark next to the Record > Pause command.
To resume recording:
-- Click Pause again.
----Always resume recording with the application-under-test in the same
state that it was in when you paused.
45. How to end the recording of a script?
Click the Stop Recording button on the GUI Record toolbar.
46. How to define script properties?
1. Do one of the following:
. If the script is open, click File > Properties.
. If the script is not open, click File > Open > Script. Select the
script and click the Properties button.
2. In the Script Properties dialog box, define the properties. For
detailed information about an item, click the question mark near the
upper-right corner of the dialog box, and then click the item.
3. Click OK.
47. How to code a script manually?
1. In Robot, click File > New > Script.
2. Type a script name (40 characters maximum) and, optionally, a
description of the script.
3. Click GUI.
4. Click OK. Robot creates an empty script with the following lines:
Sub Main
Dim Result As Integer
'Initially Recorded: 01/17/05 14:55:53
'Script Name: GUI Script
End Sub
5. Begin coding the GUI script.
48. How to add a new action to an existing script?
1. If necessary, open the script by clicking File > Open > Script.
2. If you are currently debugging, click Debug > Stop.
3. In the Script window, click where you want to insert the new actions.
Make sure that the application-under-test is in the appropriate state to
begin recording at the text cursor position.
4. Click the Insert Recording button on the Standard toolbar. The Robot
window minimizes by default, or behaves as specified in the GUI Record
Options dialog box.
5. Continue working with the application-under-test as you normally do
when recording a script.
49. How to add a feature to an existing GUI script?
1. If necessary, open the script by clicking File > Open > Script.
2. If you are currently debugging, click Debug > Stop.
3. In the Script window, click where you want to insert the feature. Make
sure that the application-under-test is in the appropriate state to
insert the feature at the text cursor position.
4. Do one of the following:
- To add the feature without going into recording mode, click the Display
GUI Insert Toolbar button on the Standard toolbar. The Robot Script
window remains open. - To start recording and add the feature, click the
Insert Recording button on the Standard toolbar. The Robot window
minimizes by default, or behaves as specified in the GUI Record Options
dialog box. Click the Display GUI Insert Toolbar button on the GUI Record
toolbar.
5. Click the appropriate button on the GUI Insert toolbar.
6. Continue adding the feature as usual.
50. How to set and clear breakpoints?
1. If necessary, open a script by clicking File > Open> Script.
2. Place the pointer on the line where you want to set a new breakpoint
or clear an existing breakpoint. You can only place a breakpoint on a
line where an SQABasic command is executed. Breakpoints on comments,
labels, and blank lines are not supported. Also, there are a very few
commands that do not support breakpoints (for example, Dim and Sub).
3. Click once to insert a blinking text cursor. (You can also highlight
the entire line or any part of the line.)
4. Click Debug > Set or Clear Breakpoint. If you set a breakpoint, Robot
inserts a solid red circle in the left margin or highlights the line. If
you clear a breakpoint, Robot removes the circle or highlighting.
5. If you set a breakpoint, click Debug > Go. Robot executes as far as
the breakpoint, and then displays a yellow arrow in the left margin of
that line or highlights the line.
51. How to insert a timer while recording or editing a script?
1. Do one of the following:
. If recording, click the Display GUI Insert Toolbar button on the GUI
Record toolbar. . If editing, position the pointer in the script and
click the Display GUI Insert Toolbar button on the Standard toolbar.
2. Click the Start Timer button on the GUI Insert toolbar.
3. Type a timer name (40 characters maximum) and click OK. If you start
more than one timer, make sure you give each timer a different name.
4. Perform the timed activity.
5. Immediately after performing the timed activity, click the Stop Timer
button on the GUI Insert toolbar.
6. Select a timer name from the list of timers you started and click OK.
52. How to insert a log message into a script during recording or
editing?
1. Do one of the following:
. If recording, click the Display GUI Insert Toolbar button on the GUI
Record toolbar.
. If editing, position the pointer in the script and click the Display
GUI Insert Toolbar button on the Standard toolbar.
2. Click the Write to Log button on the GUI Insert toolbar.
After playback, you can view logs and messages using TestManager.
53. How to Choose Network Recording?
1. Click Tools Tools Tools Tools > Session Record Options Session Record
Options Session Record Options Session Record Options.
2. Click the Method Method Method Method tab, and click Network recording
Network recording Network recording Network recording.
3. Optionally, click the Method:Network Method:Network Method:Network
Method:Network tab, and select the client/server pair that you will
record. The default is to record all of the network traffic to and from
your computer.
4. Optionally, click the Generator Filtering Generator Filtering
Generator Filtering Generator Filtering tab to specify the network
protocols to include in the script that Robot generates.
54. How to set up and use proxy recording?
# Start Robot on the proxy computer.
# In the Proxy Administration dialog box, match up the proxy computer and
port with each server to be used in the test.
# In the Method:Proxy Method:Proxy Method:Proxy Method:Proxy tab of the
Session Record Options dialog box, match up each client with the server
it will send requests to. Be sure to specify the actual server and not
the proxy computer.
# Configure each client to send requests to the proxy computer, not to
the server. For example, if the client will be sending requests to an
Oracle database, use the Oracle client configuration software to specify
the proxy computer’s address and port number, not the server’s.
# On each client computer, a tester should start the client application
and navigate to the point where recording will begin.
# On the proxy computer, enable recording (File File File File > Record
Session Record Session Record Session Record Session).
# With recording enabled, each tester at each client computer performs
the transactions to record.
# When all transactions are complete, stop recording on the proxy
computer.
55. How to create a proxy computer?
1. Click Tools Tools Tools Tools > Session Record Options Session Record
Options Session Record Options Session Record Options.
2. Click the Method Method Method Method tab and make sure that Proxy
recording Proxy recording Proxy recording Proxy recording is selected.
3. Click the Method:Proxy Method:Proxy Method:Proxy Method:Proxy tab.
4. Click Proxy Admin Proxy Admin Proxy Admin Proxy Admin.
5. In Proxy:Port Proxy:Port Proxy:Port Proxy:Port, specify the proxy
computer’s port number. Note that Robot has already detected and
specified the proxy computer’s name. You can specify any available port
number. Avoid the well-known ports (those below 1024). If you specify a
port number that is unavailable, Robot prompts you for a new port number.
6. In the Server:Port Server:Port Server:Port Server:Port list, select a
server involved in the test.
7. Click Create Proxy Create Proxy Create Proxy Create Proxy.
56. How to add a client or server computer?
If you are using network or proxy recording, and the computer that you
want to use is not listed in the Method Network and Method Proxy tabs,
you can add it to the list.
1. Click Tools > Session Record Options
2. Click the Method:Network tab or Method:Proxy tab, depending on whether
you are adding a computer for network or proxy recording.
3. Click Manage Computers.
4. Click New.
5. In the Name box of the Computers group, type a name to associate with
the network name of the computer that you are adding. You can assign any
name up to 40 characters.
6. Type the computer’s network name.
7. Optionally, click Ping to make sure that the network name you just
typed is correct. If it is correct, -Successful Ping of network name-
appears in the status bar.
8. Select Client System to list this computer as a client. Select Server
System to list this computer as a server. You can select both choices.
9. Click Add.
10. Take the following steps to use a port number with the network name.
A port number is required for servers used in proxy recording:
a. In the Ports Ports Ports Ports group, type a name to associate with
the port number that you are adding. You can assign any name up to 40
characters.
b. Type the port number to use with the computer’s network name.
c. Click Apply, then OK .
11. Click Close Close Close Close.
57. How to Recording a Single Script in a Session?
1. In Robot, click the Record Session button. Alternatively, click File >
Record Session, or press CTRL+SHIFT+R.
2. Ty p e t h e session name (40 characters maximum), or accept the
default name. You will specify the script name when you finish recording
the script. If you have not yet set your session recording options, do so
now by clicking Options.
3. Click OK in the Record Session - Enter Session Name dialog box. The
following events occur:
. Robot is minimized (default behavior).
. The Session Record floating toolbar appears (default behavior). You can
use this toolbar to stop recording, redisplay Robot, split a script, and
insert features into a script.
. The Session Recorder icon appears on the taskbar. The icon blinks as
Robot captures requests and responses.
4. If the Start Application dialog box is displayed, provide the
following information, and click OK:
. The path of the executable file for the browser or database
application.
. Optionally, the working directory for any components (such as DLLs)
that the client application needs at runtime.
. Optionally, any arguments that you want to pass to the client
application. The Start Application dialog box appears only if you are
performing API recording, or if you are performing network or proxy
recording and selected Prompt for application name on start recording in
the General tab of the Session Record Options dialog box.
5. Perform the transactions that you want to record. As the application
sends requests to the server, notice the activity in the Session Recorder
window. Progress bars and request statistics appear in the top of the
window.
If there is no activity in the Session Recorder window (or if the Session
Recorder icon never blinks), there is a problem with the recording. Stop
recording and try to find the cause of the problem.
6. Optionally, insert features such as blocks and timers through the
Session Insert floating toolbar or through the Robot Insert menu.
7. Optionally, when you finish recording transactions, close the client
application. With API recording, when you close the client, Robot asks
whether you want to stop recording. If so, click Yes, and either name the
session or click to ignore the recorded information in the Generating
Scripts dialog box.
8. Click the Stop Recording button on the Session Record floating
toolbar.
58. How to stop recording and generate scripts in a Session?
1. Click the Stop Recording button on the Session Record floating
toolbar.
2. In the Name of the just-recorded script box, type or select a name for
the script that you just finished recording, or accept the default name.
3. Click OK.
59. How to see error message If problems occur during script generation?
the error message appears in the status bar of the Generating Scripts
dialog box like this: "Completed with warnings and/or errors"
To see the list of errors, click Details. If the text of an error is
truncated, you can either:
. Double-click the text to see the entire message.
. Press CTRL+C to copy the text to the Clipboard.
60. How to cancelling a Script in a Single-Script Session?
1. During recording, click the Stop button on the Session Record floating
toolbar.
2. In the Stop Recording dialog box, click Ignore just-recorded
information.
3. Click OK in the Stop Recording dialog box.
4. Click OK to acknowledge that the session is being deleted.
61. When would you want to split a session?
If quick script development time is a priority - perhaps because testable
builds are developed daily, or because web content is updated daily.
62. How to split a session into multiple scripts?
1. During recording, at the point where you want to end one script and
begin a new one, click the Split Script button on the Session Record
floating toolbar.
2. Enter a name for the script that you are ending, or accept the default
name.
3. Click OK.
4. Repeat the previous steps as many times as needed to end one script
and begin another. 5. After you click the Stop Recording button to end
the recording session, type or select a name for the last script you
recorded, or accept the default name.
63. How to regenerate Scripts from a Session?
1. In Robot, click Tools > Regenerate Test Scripts from Session.
2. Click the name of the session to use.
3. Click OK to acknowledge that the regeneration operation is complete.
64. How Timers Work?
1. Start the timer (click Insert--Start Timer) just before you click the
button to send the query. This action inserts the VU emulation command
start_time into the script.
2. Stop the timer (click Insert --Stop Timer) as soon as the results
appear. This action inserts the VU emulation command stop_time into the
script.
65. What is a block?
A block is a set of contiguous lines of code that you want to make
distinct from the rest of the script.
66. What is a blocks characteristics?
# A block begins with the comment. In the VU language, a block begins
like this:
/* Start_Block "BlockName" */
# Robot automatically starts a timer at the start of the block. In the VU
language, the timer looks like this:
start_time ["BlockName"] _fs_ts;
Typically, the start_time emulation command is inserted after the first
action, but with an argument to use a read-only variable that refers to
the start of the first action.
# The ID of every emulation command in a block is constructed the same
way that is, by the block name followed by a unique, three-digit
autonumber. For example, in the VU language:
http_header_recv ["BlockName002"] 200;
When you end a block, command IDs are constructed as they were before you
started the block. For example, if the last command ID before the block
was Script025, the next command ID after the block will be Script026.
# A block ends with a stop_time command plus a comment. For example, in
the VU language:
stop_time ["BlockName"]; /* Stop_Block */
67. Why Use Blocks?
. To associate the block and timer names with the emulation command that
performs the transaction.
. To include the block name in TestManager reports, thus enabling you to
filter the reports with the block name.
.To make the script easier to read, and to provide an immediate context
for a line within the block through command IDs.
68. How to insert a block into a script?
1. If the Session Insert floating toolbar is not already displayed, click
the Insert button on the Session Record floating toolbar.
2. Click the Start Block button at that point in the script where you
want the block to begin for example, just before you start to record a
transaction.
3. Type the block name. Robot uses this name as the prefix for all
command IDs in the block. The maximum number of characters for a command
ID prefix is seven.
4. Click OK.
5. Record all of the client requests in the block.
6. Click the Stop Block button to end the current block, and click OK.
7. Continue recording the other sections of the script. When you start
and stop a block during recording, the commands are reported as
annotations in the Annotations window.
69. What is A synchronization point?
A synchronization point lets you coordinate the activities of a number of
virtual testers by pausing the execution of each tester at a particular
point
70. Why Use Synchronization Points?
By synchronizing virtual testers to perform the same activity at the same
time, you can make that activity occur at some particular point of
interest in your test. Typically, synchronization points that you insert
into scripts are used in conjunction with timers to determine the effect
of varying workload on the timed activity.